Description

FTU-P100/R100

FTU-100 series of P&C Technologies behave IED (Intelligent Electronic Device) for distribution automation, which is a fullydigitalized and microprocessor-based control device. Basic functions of FTU are controlling of LBS (Load Break Switch)and Recloser, status monitoring, and measuring of electric values. All these functions are performed from remote controlcenter through communication.

FTU-100 series have 3 different models according to the switch to which each model is applied.

  1. FTU-P100 is Pole-topLoad Break Switch Control.
  2. FTU-R100 is Automatic Circuit Recloser Control.
  3. FTU-GD100 is Feeder RTU for Pad-mounted Multiple-circuits Load Break Switch.

Features & Functions

FTU-100seriesadopt Fault Detection schemes for Phase fault (A/B/C), Ground fault (N), and even Sensitive Earth fault (SEF).Especially, FTU-R100 supports protection and reclosing functions, such as 48 types of built-in editable TC curves, instantaneous &time-delayed protection elements for phase or ground faults including SEF, auto-reclosing up to 3 shots, and sequencecoordination with other devices. And, Cold Load Pickup and Inrush Restraint functions distinguish the fault current and the normalload current. As equipped with fully configurable setting value ranges, FTU-100 series can be used as Distribution Automationequipment in various faulted environments for the rapid fault restoration and blackout minimization.

Fault Detection / (*)Protection & Auto-Reclosing

  • Fault Detection (Phase Fault / Earth Fault / SEF)
  • 48 types of built-in configurable TC Curves (*)
  • Fast / Time-delayed OC(G)R & HCT (High Current Trip) (*)
  • Auto-Reclosing (up to 3 shots) (*)
  • Sequence Coordination (*)
  • Cold Load Pickup & Inrush Restraint
  • Open Line Detection & Phase Sync Fail Detection (Va - Vr)
    (Source-side & Load-side)

Measurement

  • Voltage(Source/Load) & Current (3-phase RMS / True RMS)
  • Power (kVA, kW, kVar) & Energy (kWh, kVarh)
  • Power Factor, Frequency, Phase Angle
  • Harmonics (up to 8th) & THD (Total Harmonic Distortion)

Control

  • Control Position : Local / Remote
  • Switch Control : Open / Close (SBO / DO) after Select
  • FI (Fault Indication) Manual Reset, Battery Test
  • Reclosing & Protection Function Blocking (*)

Status Monitoring

  • Switch Status : Open / Closed
  • Control Position : Local / Remote
  • Fault Indication (A/B/C/N/SEF/HCT(*) / Reverse Dir.)
  • Open Line & Sync Fail, Hot Line, Inrush Detected
  • Reclosing Status : Ready / Progress / Lockout (*)
  • Switch Handle Locked & Gas Pressure Low
  • External AC Power Loss, Enclosure Door Open
  • Battery Overdischarged & Charging Circuit Error
  • System Error (Self Diagnosis Result)

Counter

  • FTU Restart Count, Switch Trip Count
  • Fault Count (Total/A/B/C/N)

Recording

  • Over 2,000 Events (I/O, Functional, System, Fault)
  • Fault Waveform (Current & Source-side Voltage)
  • * up to 4 faults : 10 cycles/record & 32 samples/cycle
  • Demand Current & Power, Max Current & Power

Communication Protocols

  • SCADA : DNP3.0, IEC60870-5-101 (optional)
  • Setting & Maintenance : Modbus

FTU-GD100

FTU-GD100 performs RTU and distribution automation functions for Pad-mounted Multiple-circuits Load Break Switch. Basic model is for 4 circuits.Local Controller is directly connected to LBS and CT/PT inputs, and it has control (open/close) buttons, local/remote control position change switch,control lock/unlock switch, and LBS status LED indicators on the front panel. FTU-GD100 is connected to Local Controller through several connectors,and receives voltage/current inputs and LBS status information. Using this information, FTU-GD100 measures or calculates electric values, generateslogical status data, and transmits all information to Master system (DAS: Distribution Automation System) through communication network. For remotecontrol, FTU-GD100 receives control action command from Master system and sends control output to LBS through Local Controller. FTU-GD100 andLocal Controller are installed inside the enclosure of Pad-mounted LBS.


Product Image

  • Feeder Terminal Unit image

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Deuy Park
P&C Technologies Co., Ltd.
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Other Electrical Equipment
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838