Load Break Switch

Inquire now

Load Break Switch

Click to enlarge image

 Model Number Pole LBS

Overview

SF6 gas Insulated Load Break Switch (LBS) for overhead lines operates at a voltage up to 25.8kV. It meets the demand for oil-lessand maintenance free operation with SF6 gas, the related parts and devices installed inside its hermetically sealed stainless steeltanks.The pole-mounted LBS can be manually operated or motorized for fault isolation, remote control and automation to suit your powerline requirements. The pole-mounted LBS has been fully certified in accordance with IEC 60694(1996), IEC 60265(1998) to meetand exceed customer's requirement.

General Specification

Description
10~15 kV class
20~27 kV class
Operating Method
Auto/Motorized/Manual
Auto/Motorized/Manual
Rating
Voltage
12/15 kV
24/25.8 kV
Current
400/630 A
400/630 A
Frequency
50/60 Hz
50/60 Hz
Short time Withstand Current (4 sec)
20 kA
12.5/16 kA
Making Capacity (peak)
50 kA
32/50 kA
Number of Making
5 times
5 times
Breaking Capacity
Mainly Active Load Breaking
400/630 A
400/630 A
Loop Current Breaking
400/630 A
400/630 A
Transformer Magnetizing Current
14/22 A
14/22 A
Cable Charging Current (rms. Sym)
31.5 A
25 A
Line Charging Current
2 A
1.5 A
Impulse Insulation
Level (1.2x50µs)
Phase to Earth
75 kV
150 kV
Across Interrupter
85 kV
150 kV
Power Frequency Insulation Level
Phase to Earth
42 kV
60 kV
Across Interrupter
49 kV
60 kV
Control Source Voltage
AC 220/DC 24 V
AC 220/DC 24 V
Rated Gas pressure at 20°C
1.0 kgf/㎠G
1.0 kgf/㎠G
Endurance
With Current (at rated current)
400 times
400 times
Without Current
5000 times
5000 times
Weight
Switch Body without Mounting Frames
110 kg (Auto-type)
130 kg (Auto-type)
Control Box
57 kg
Applied Standard
IEC 60265-1, ANSI C37.71

Related Keywords: Load Break Switch