Click to enlarge image
|
Product Introduction
-
25.8kV Gas Insulated Switchgear with single bus, developed with our continuous research and development, will be provided to domestic and international markets
- All the units of SF6 Gas Insulated Switchgear(GIS) from our company are equipped in a
grounded metal pressure vessel featuring the highest performance, high availability for real
systems and detachable single pole metal-enclosed , and its main circuit is insulated by an
inactive gas, SF6 having no color, taste, odor and toxicant.

Characteristic
|
High Reliability
|
All the components sealed with SF6 gas guarantees no deterioration and semi-permanent high performance |
|
Safety
|
Active units built in the grounded metal case ensures the safety of workers during operation and maintenance |
|
Convenient Maintenance
|
Due to no deterioration at the components surrounded by SF6 gas, long term based maintenance is enough to ensure the compatibility for the product maintenance. |
|
Reduced Installation Area
|
The effective installation area, enabled by reducing the width of unit circuit which determines the installation area. |
|
Reduced Plan and deployment time
|
Reduced planning, manufacturing and delivery time, enabled by a combination of standard components |
|
Environment- friendly combination
|
Superior modern environment-friendly combination featuring its tidy figure, low noise, minimized induction fault. |
Specification
|
Rated voltage
|
kV
|
24/25.8 |
|
Proper frequency
|
Hz |
60 |
|
POWER FREQUENCY
WITHSTAND VOLTAGE between the charging unit
and earth and between disconnectors
|
kV,rms |
50
60 |
|
LIGHTING & SWITCHING IMPULSE WITHSTAND
VOLTAGE between the charging unit and earth and between disconnectors.
|
kV,crest |
125(150bic)
145(175bic) |
|
Rated current
|
A,rms |
600,1200,2000,
2500,3000
※ |
|
Rated short time current
|
kV,rms |
25 |
|
Operating type
Breaker
Three step switchgear(Disconnector, Grounding
switchgear)
|
|
Electric/Manual Electric/Manual |
|
Guaranteed times
100% cut-off current
Rated current
|
times
|
100
10000 |
|
Rated cut-off time
|
Cycle |
3/5 |
|
Standard operating responsibility
|
|
0-0.3Sec-CO-3Min-CO |
|
Rated gas pressure
Gas pressure guaranteeing stable performance
Gas leakage rate
Design pressure in gas vessel
Operating pressure of safety device in room
|
Bar.G,20 °C
Bar.G,20 °C
% /Year
Bar.G |
0.5/1.0
0.3/0.8
less than1
0.9/1.4
3.8 |
※ To order higher spec. than above, contact our company
|
|
|
|
| |
|
|
|